Clearance
Surge arrester type 1+2+3, ETITEC VS T123 255/25 4+0 RC leakage current-free, (TN-S)
CHF 1,209.57
Price for:
1 Piece
Accessories for surge arrester type 1+2+3, ETITEC VS T123 255/25 4+0 RC leakage current-free, (TN-S)
Bow.
CHF 18.16
Clearance
Delivered on Tuesday
Delivered on Tuesday
19
Stock Availability
19 Piece Still in Stock
While Supplies Last
This item is being cleared out and will not be restocked.
Item number:
64370
Manufacturer number:
002442935
Your advantages with Normrahmen AG
Free shipping from 79 CHFwithin Switzerland
Production & Developmenthigh quality products
Everything from a single source60 day return policy
Attractive cost advantagesthanks to our own production
Product information "Surge arrester type 1+2+3, ETITEC VS T123 255/25 4+0 RC leakage current-free, (TN-S)"
Type 1+2+3 combined arrester based on a gas-filled spark gap
Leakage capacity per pole: Iimp= 25 kA (10/350 µs)
Safe disconnecting device
Saves energy costs Does not generate any (mains) follow current Operational and leakage current-free
VDE-AR-N 4100 compliant "Use of type 1 surge protective devices (SPD) in main power supply systems"
Energy-coordinated
Remote signalling as standard
Complies with the IEC 61643-11 and EN 61643-11 standards
Leakage capacity per pole: Iimp= 25 kA (10/350 µs)
Safe disconnecting device
Saves energy costs Does not generate any (mains) follow current Operational and leakage current-free
VDE-AR-N 4100 compliant "Use of type 1 surge protective devices (SPD) in main power supply systems"
Energy-coordinated
Remote signalling as standard
Complies with the IEC 61643-11 and EN 61643-11 standards
Item number: | 64370 |
---|---|
Manufacturer number: | 002442935 |
Applied technology: | MOV & GDT |
I imp (10/350) Maximum pulse current: | 100kA |
I imp (10/350) Pulse current: | 25kA |
I max (8/20): | 70kA |
In (8/20): | 30kA |
Integrated back-up fuse: | No |
Interchangeable surge modules: | No |
Leakage current free: | Yes |
Net shape: | TN-S |
---|---|
No back-up fuse required until: | 315A |
Number of modules: | 8 |
Type: | T1, T2 & T3 |
Uc Continuous operating voltage: | 255V |
Uoc (1.2/50 - 8/20) Overvoltage peak: | 20kV |
Up - Voltage protection level: | < 1.5kV |
With remote signalling contact: | Yes |