Product information "Energy meter EMU Professional 3/5, Modbus, MID B+D approval, transformer measurement 3PN"
The EMU Professional 3/5 Modbus 3-phase measuring transformer meter has an integrated RS485 Modbus RTU and ASCII interface and is suitable for energy cost billing and energy management in accordance with ISO 50001.
Modbus RTU and ASCII interface
The Modbus RTU and ASCII interface is integrated into the EMU Professional 3/5 and protected against dirt and tampering. Modbus RTU (Remote Terminal Unit) transmits the data in binary form. Modbus ASCII transmits the data in ASCII code. The EMU Professional communicates via Modbus at 9,600, 19,200, 38,400, 57,600 and 115,200 baud.
Functions at a glance
-MID B+D, ex works for billing purposes
-Bidirectional three-phase meter with S0 pulse output
-3x230/400V
-Accuracy class B (1%)
-RS485 Modbus RTU interface
-High load Opto Power MOSFET S0 pulse output, 5-230V AC or V DC, max. 90 mA
-1 or 5 A current transformer connection for up to 20000/5 or 4000/1 A
-2 tariff (day / night), tariff switching via 230V signal
Measured values can be called up on the energy meter
-Active power (kw)
-Reactive power (kvar)
-Apparent power (kVA)
-Current (A)
-Active energy consumption (kWh) and delivery (kWh)
-Reactive energy inductive (kvarh) and capacitive (kvarh)
-Mains frequency (Hz)
-Number of voltage failures
Adjustable pulse rate and time:
-Pulse length in milliseconds: 4 to 250 ms, adjustable in 2 ms increments
-Pulse rate per kWh: 0.001, 0.01, 0.1, 1, 10, 100, 1000 or 10000
Current transformer ratio
The current transformer ratio can be configured several times via buttons. The service button can be sealed.
-Current transformer /1 A 1/1 A to 4,000/1 A in 1 A increments -Current transformer /5 A 5/5 A to 20,000/5 A in 5 A increments
Configuration ex works
-Transformer connection: 10 pulses/ 120 ms
Connection: 3ph. transformer/5 and 1A
Interface: Modbus RTU, RS 485
Approval: MID B+D
Modbus RTU and ASCII interface
The Modbus RTU and ASCII interface is integrated into the EMU Professional 3/5 and protected against dirt and tampering. Modbus RTU (Remote Terminal Unit) transmits the data in binary form. Modbus ASCII transmits the data in ASCII code. The EMU Professional communicates via Modbus at 9,600, 19,200, 38,400, 57,600 and 115,200 baud.
Functions at a glance
-MID B+D, ex works for billing purposes
-Bidirectional three-phase meter with S0 pulse output
-3x230/400V
-Accuracy class B (1%)
-RS485 Modbus RTU interface
-High load Opto Power MOSFET S0 pulse output, 5-230V AC or V DC, max. 90 mA
-1 or 5 A current transformer connection for up to 20000/5 or 4000/1 A
-2 tariff (day / night), tariff switching via 230V signal
Measured values can be called up on the energy meter
-Active power (kw)
-Reactive power (kvar)
-Apparent power (kVA)
-Current (A)
-Active energy consumption (kWh) and delivery (kWh)
-Reactive energy inductive (kvarh) and capacitive (kvarh)
-Mains frequency (Hz)
-Number of voltage failures
Adjustable pulse rate and time:
-Pulse length in milliseconds: 4 to 250 ms, adjustable in 2 ms increments
-Pulse rate per kWh: 0.001, 0.01, 0.1, 1, 10, 100, 1000 or 10000
Current transformer ratio
The current transformer ratio can be configured several times via buttons. The service button can be sealed.
-Current transformer /1 A 1/1 A to 4,000/1 A in 1 A increments -Current transformer /5 A 5/5 A to 20,000/5 A in 5 A increments
Configuration ex works
-Transformer connection: 10 pulses/ 120 ms
Connection: 3ph. transformer/5 and 1A
Interface: Modbus RTU, RS 485
Approval: MID B+D
Item number: | 60719 |
---|---|
Accuracy class: | B |
Calibrated: | Yes |
Characteristic: | B |
Energy type: | Active energy supply, active energy purchase & Reactive energy |
Execution of the interface: | Modbus RTU RS485 |
Illuminated display: | Yes |
MID: | MID B+D |
Maximum current (Imax): | 20000A |
Meter type: | Electronic |
Mounting type: | REG (top-hat rail) |
---|---|
Number of modules: | 5 |
Polar type: | Four-wire |
Protection class: | IP 20 |
Pulse type: | S0 |
Suitable for energy management in accordance with ISO 50001: | Yes |
Tariff execution: | Double tariff |
Width in pitch units: | 5 Module |
Contact person
If you have any questions, feel free to contact our representatives.

DE
Tobias Schneider
Head of Product Development and Consultancy, Management Board
- Do you have any questions about this product?
- E-Mail: tobias@normrahmen.ch
- Phone: +41 31 744 10 42